Use:

The low-emission steam boiler VSPK is designed for the production of steam with nominal working overpressure of steam up to 1.6 MPa with the possibility of fitting the steam superheater up to the temperature of superheated steam 240 ° C. VSPK boilers with their dimensions replace the well-proven ČKD BK boilers and therefore do not require demanding installation. The robust construction, high efficiency, simple installation, long operating life and low NOx emissions together with other operating characteristics make the VSPK boilers one of the top products. The boilers can be equipped with the device for operation without continuous operators.

 

Kotel VSPK 2.jpg

Technical description:

The VSPK fire-tube boiler is large-volume, with natural circulation and pressurized combustion. It is designed as three-draught. The boiler body consists of two steel cylinders welded to the front and rear walls. The combustion chamber is cylindrical, water-cooled. On the rear wall, the flue gas is reversed, which passes into the second draught and returns to the front wall by means of the heat tubes, where it is turned into a third draught formed by the heat tubes. If the steam superheater is used, the superheater is mounted in the boiler's reversing chamber. The front opening lid and the rear manhole provide easy access to the heating surfaces, their cleaning and inspection.
The boiler is equipped with insulation and all legal equipment. The boiler is plated with aluminium sheet.

Low-emission steam boiler  VSPK

2

4

6

8

10

12

Fuel

Natural gas

Nominal steam output

t/h

2

4

6

8

10

12

Nominal heat output

MW

1,35

2,7

4,0

5,4

6,7

8,0

Nominal pressure

MPa

1,6

1,6

1,6

1,6

1,6

1,6

Feed water temperature

°C

105

105

105

105

105

105

Boiler efficiency with economizer up to

%

97

97

97

97

97

97

 NOx emissions ( 3% O2) MAX

mg.mˉ³

80

80

80

80

80

80

Volume of water

5,32

8,9

9,8

12,9

13,2

13,5

Transport weight

t

7

13

15

18

22

23

Dimensions

Boiler length

L

mm

4400

6000

7400

7400

8000

8500

Boiler width

B

mm

2530

2930

3100

3400

3500

3800

Boiler height

H

mm

3000

3200

3500

4100

4100

4200

Water input / steam output

PN16/40

DN

25/80

25/100

40/125

40/150

50/150

50/200

 

Download:Steam fire-tube boiler VSPK.pdf